Permanent offline monitoring

SENSOR DDS® LMS

The SENSOR DDS® LMS is system developed by Sensor s.r.o. where regular/irregular grid of sensors is installed permanently into the ground below the geomembrane.

The sensors are usually installed with grid of 8x8m depending on site conditions and client’s requirements. The general rule saying denser the grid, the more accurate the damage will be located.

The sensors are non-metal, made from specially developed conductive polyethylene (HDPE) with specific electrical parameters what allows us to monitor the distribution of the current flow below the geomembrane.

The SENSOR DDS® LMS is offline system which means that the integrity of the geomembrane must be tested by Sensor technician directly on site. Any defects would be detected and located in testing phase and then exposed and repaired by geomembrane installation contractor.

After system installation, the integrity of the geomembrane can be checked in regular intervals upon agreement with the client. The certificate of the integrity will be issued by Sensor after each test.

Click here to see the example project

The benefits of SENSOR DDS® LMS
offline permanent monitoring

Permanent Monitoring

Permanent control over integrity of installed liner. Can be installed in association with any type of (non-conductive) liner / moisture barrier

Fast Measurements

Quick on-site measurement process.

No Covering Limitations

Not limited by depth or type of covering to the liner installation as with portable dipole system

Responsibility

In any storage situation where contamination of, or by, the stored product is unacceptable the liner can be safely ruled out as the cause of the problem.

SENSOR DDS® LMS
SENSOR DDS® LMS

SENSOR DDS® LMS permanent monitoring applications

SENSOR DDS LMS is offline system permanently built into the design of the waterproofing layer. Among the most used applications are:

  • Flat roofs
  • Ponds
  • Water Reservoirs
  • Building Foundations
  • Balconie
  • Mining Pond
  • Tunnel
  • Bridges
  • Landfills
  • Landfill capping
  • Industrial lagoons
  • Dams

SENSOR DDS® LMS measurement can be done in specified intervals

Installation of Sensor fixed system using certified components with lifespan of min. 30 years

Qualified and experienced Sensor engineers are crucial in data interpretation

SENSOR DDS® LMS permanent system is installed before geomembrane is laid down

Monitoring of geomembrane at landfill during first phases plays mandatory role in overall QC

Onsite measurement of liner integrity using built-in grid of sensors is performed with SENSOR DDS® LMS portable testing equipment

The standard Sensor offline monitoring panel can consists of 50 – 256 sensors

When leak is located using Sensor fixed system, its accurate GPS coordinates are provided